Error messages

When multiple MODEL 10 units are connected by F.C.B.S., the error messages described in the table below may be displayed on the display. In such a case, ID setting or remote cable connection may be in failure. Check the ID or remote cable connection, referring to the table below. For details on ID setting, see How to set ID for F.C.B.S.link.

Error Code

Meaning

Cause / Solution

001

Multiple amplifiers take ID “Member 1”.

Assign different IDs to the amplifiers.

002

Multiple amplifiers take ID “Member 2”.

003

Multiple amplifiers take ID “Member 3”.

011

The amplifiers with ID “Member 1 - 3” cannot communicate with the amplifier with ID “Leader”.

If the amplifier with ID “Leader” is not on, turn it ON.

Check that the remote cable is properly connected.

012

The amplifier with ID “Leader” cannot communicate with the amplifiers with ID “Member 1 - 3”.

If multiple amplifiers take ID “Leader”, set IDs properly.

If the amplifier with ID “Leader” is connected to the amplifier with ID “Off”, set IDs properly.

Check that the remote cable is properly connected.

back to top